Etape 1 - Calcul du Debit d'air
Thermique :-
Empirique :-
Brassage :-
Q = Phi / (rho.Cp.DT) = Phi(W) / (1200 x DT) x 3600
Etape 2 - Diametre de Gaine
Reco residentiel : 3-4 m/s
Calcule :-
Section :-
V reelle :-
D = sqrt(4Q / pi.v) | Standards : 80,100,125,160,200,250,315,400,500,630,800,1000,1250 mm
Etape 3 - Plenum
V plenum < V gaines
Repartition x1.5
-
mm (reco)
DTU 68.3 : Verifier perte de charge (Pa/m) avant validation
VMC Simple Flux - RT2012 / RE2020
Reference - Debits DTU 68.3 (arrete 24/03/1982)
| Pieces | Cuisine | SDB | WC | Total min |
| 1 | 75 | 15 | 15 | 35 |
| 2 | 90 | 15 | 15 | 60 |
| 3 | 105 | 30 | 15 | 75 |
| 4 | 120 | 30 | 15 | 90 |
| 5 | 135 | 30 | 15 | 105 |
| 6 | 135 | 30 | 15 | 120 |
| 7+ | 135 | 30 | 15 | 135 |
Debits m3/h - Source : Arrete 24 mars 1982, DTU 68.3
Hygrometre - Calculs psychrometriques
Pvs :-
Pv :-
x :-
h :-
Pvs=exp(23.3265-3802.7/(T+273.18-46.68))
Pv=Pvs(Th)-A.P.(Ts-Th), A=6.66e-4
Point de Rosee & Condensation
Risque :-
Ecart :-
T surf min :-
Confort :-
Magnus-Tetens : Tr=(b.a)/(a-a), a=17.27, b=237.7
Simulation CO2 - Qualite Air Interieur
Production :-
Renouvellement :-
Equilibre :-
<600
Excellent
600-800
Bon
800-1k
Moyen
1k-1.5k
Mediocre
>1500
Mauvais
C(t) = Ce + (S/Q)(1-e^(-Qt/V)) | EN 16798 <1000ppm | RE2020 25m3/h/pers